For Designers / 29 August 2026

How to Check a Blast-Protection Certificate

A checklist for doors, windows and structures assessed against GOST R 57471-2017, amendments 1 and 2.

If there is no documentary evidence, do not assume that testing took place. Check four points before specifying or purchasing a product.

The Russian article references Federal Laws No. 412-FZ of 28 December 2013 and No. 184-FZ, Articles 21 and 31, and GOST R 57471-2017 clauses 9.4.1, 9.5.1, 9.5.4, 9.7.1, 9.9.5.1, 9.9.5.2, 9.12.2 and 9.12.5. Check the applicable current texts and project requirements rather than relying on a paper certificate alone.

Verify the document and issuing body's accreditation in the official Federal Accreditation Service register.

1. Accreditation for the Relevant Standard

Inspect: the certification body's accreditation scope, not just the certificate. It should explicitly cover GOST R 57471-2017.

Request: a copy of the accreditation scope together with the certificate. Cross-check the organisation and accreditation number in the official register.

Warning signs: the standard is missing from the scope, the body cannot be found in the register, or the scope is withheld.

2. Photographs and Video of Successful Testing

Inspect: photographic and video attachments to the blast-test report. This is particularly important for higher protection classes and large-charge tests. For doors, normal opening after the blast matters because a jammed door can obstruct evacuation.

Request: photographs before and after testing and video of the detonation and subsequent door opening. Missing video is a reason to request further evidence.

Warning signs: a report saying only that no damage occurred, without images or video; no record of post-blast door opening.

3. Protection Class, Not a Trade Name

Inspect: the report's conclusion. It should assign a specific protection class and category under the standard, rather than repeat a commercial product designation.

A product name containing a class-like identifier is not itself evidence of an assigned protection class.

Request: the assigned class and category in the certificate and test report, not only the model or stock code.

Warning signs: a general statement of compliance or a pressure value without an assigned protection class and category.

4. Tested Specimen Dimensions

Inspect: the specimen dimensions in the report and the stated scope of the results. A small tested leaf does not establish the performance of a large gate.

Request: leaf and opening width and height, and confirmation that the proposed product falls within the tested and documented size range.

Warning signs: dimensions are absent or substantially smaller than the specified product.

Recommended Review Sequence

  1. Certificate and issuing body's accreditation scope.
  2. Test report with photographs and video.
  3. Assigned protection class and category.
  4. Specimen dimensions compared with the proposed product.

If any document is missing, request clarification and the missing evidence before accepting the product into the design. A responsible manufacturer should expect this request.